R&S®ESIB EMI Test Receivers

Standard-compliant EMI measurements up to 40 GHz

Features

EMC performance features

  • Fast scanning in test receiver mode and sweeping in spectrum analyzer mode
  • Compliant with CISPR 16-1-1
  • Two RF inputs
    Input 2 with additional pulse protection (20 Hz to 1 GHz)
  • Integrated 20 dB preamplifier (selectable)
    1 kHz to 7 GHz as standard; >7 GHz as option R&S ESIB-B2
  • Preselection in receiver mode (fixed) and analyzer mode (selectable)
  • Resolution bandwidths meeting MIL standards and CISPR 16 specifications
    in analyzer mode, -3 dB RBWs and -6 dB RBWs selectable
  • Parallel detectors
    Peak, average, quasi-peak, CISPR average and RMS (max. four simultaneously)
  • Automatic overload detection & autoranging
  • Editors for user-definable transducer factors/sets and limit lines
    incl. integrated transducer factor/limit line libraries
  • Internal test routines for automated or interactive preview & final measurements
  • Evaluation functions for prescan, data reduction (peak list) and final measurement
  • Split screen display (mixed analyzer/receiver mode) for detailed signal analysis
  • Convenient scan table editor
    Up to ten subranges with individual parameter setting
  • Automatic scan and display of traces in parallel (receiver mode)
    Max. four traces with up to 80.000 samples each (250.000 samples with one trace)
  • Time-domain measurements (zero span) at up to 50 ns resolution for interference source analysis

Additional highlights

  • Extensive self-calibration routines incl. result documentation
  • Interfaces: IEC/IEEE, serial, parallel, LAN (optional)
  • Comprehensive marker evaluation functions    search, delta, tune-to-marker, marker track
  • Integrated controller function under Windows NT 4.0
    printer-driver compatibility, easy hardcopy capabilities, quick firmware update
  • Internal tracking generator up to 7 GHz (option R&S FSE-B10)
  • Bright 24 cm LC color display

Noise display (30 Hz to 100 kHz) with magn. coil R&S HZ-10

Split screen display with scan results (two traces) and bargraphs (three parallel detectors)

Split screen display with scan results (two traces) and realtime spectrum analysis at marker frequency

Scan table for CISPR bands A to C/D